40
About Your System
E2113
Mem mirror OFF
on DIMM ## &
##. Power
cycle AC
The system BIOS has
disabled memory
mirroring because it has
determined one half of the
mirror has had too many
errors. "## & ##"
represents the
memory-module pair
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 177.
I1910
Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1912
System Event
Log full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
on the events, then clear
the SEL.
I1920
iDRAC6 Upgrade
Successful
Optional iDRAC6 has
been upgraded
successfully.
Information only.
W1228
RAID
Controller
battery
capacity <
24hr.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
Allow RAID battery
to charge to greater
than 24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 147.
W1627
Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power
than what the power
supply can provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Code
Text
Causes
Corrective Actions
book.book Page 40 Friday, November 20, 2009 2:56 PM
Summary of Contents for PowerEdge R510
Page 11: ...Contents 11 7 Getting Help 199 Contacting Dell 199 Glossary 201 Index 211 ...
Page 12: ...12 Contents ...
Page 82: ...82 Using the System Setup Program and UEFI Boot Manager ...
Page 188: ...188 Troubleshooting Your System ...
Page 198: ...198 Jumpers and Connectors ...
Page 200: ...200 Getting Help ...
Page 210: ...210 Glossary ...