56
About Your System
Unused memory
detected. DIMM’s
installed in the
following slot
are not available
when in 128-bit
advanced ECC
mode:
x
,
x
,
x
The memory configuration is
not optimal for Advanced
ECC Memory Mode.
Modules in the specified
slots are unused.
Reconfigure the memory for
Advanced ECC Memory
Mode, or change the
memory mode to
Optimized
or
Sparing
in the BIOS setup
screen. See "System
Memory" on page 114.
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error
occurred and caused the
system to reboot.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 169 for
any faulty components
specified in the SEL.
Warning: Control
Panel is not
installed.
The control panel is not
installed or has a faulty cable
connection.
Install the control panel, or
check the cable connections
between the display module,
the control panel board,
and the system board.
See "Integrated Storage
Controller Card" on
page 129.
Warning! No micro
code update
loaded for
processor
n
Micro code update failed.
Update the BIOS firmware.
See "Getting Help" on
page 199.
Message
Causes
Corrective Actions
book.book Page 56 Friday, November 20, 2009 2:56 PM
Summary of Contents for PowerEdge R510
Page 11: ...Contents 11 7 Getting Help 199 Contacting Dell 199 Glossary 201 Index 211 ...