36
About Your System
E1A14
SAS cable A
failure.
Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 199.
E1A15
SAS cable B
failure.
Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 199.
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable.
If the problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 199.
E2010
Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules.
See "Installing Memory
Modules" on page 119 or
"Troubleshooting System
Memory" on page 177.
E2011
Memory
configuration
failure.
Check DIMMs.
Memory detected,
but is not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 177.
E2012
Memory
configured but
unusable.
Check DIMMs.
Memory configured,
but is unusable.
See "Troubleshooting
System Memory" on
page 177.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed
to copy its flash image
into memory.
See "Troubleshooting
System Memory" on
page 177.
Code
Text
Causes
Corrective Actions
book.book Page 36 Friday, November 20, 2009 2:56 PM
Summary of Contents for PowerEdge R510
Page 11: ...Contents 11 7 Getting Help 199 Contacting Dell 199 Glossary 201 Index 211 ...
Page 12: ...12 Contents ...
Page 82: ...82 Using the System Setup Program and UEFI Boot Manager ...
Page 188: ...188 Troubleshooting Your System ...
Page 198: ...198 Jumpers and Connectors ...
Page 200: ...200 Getting Help ...
Page 210: ...210 Glossary ...