About Your System
31
E122A
CPU # VTT
Regulator
failure.
Reseat CPU.
Specified processor
VTT voltage regulator
has failed.
Reseat the processor(s).
See "Troubleshooting
Processors" on page 186.
If the problem persists,
see "Getting Help" on
page 199.
E122C
CPU Power
Fault. Power
cycle AC.
A power fault was
detected when powering
up the processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
E122D
Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 177.
E122E
On-board
regulator
failed.
Call support.
One of the on-board
voltage regulators has
failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
E1310
Fan ## RPM
exceeding
range.
Check fan.
RPM of specified fan is
outside of the intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 176.
E1313
Fan redundancy
lost.
Check fans.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
overheating.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 176.
Code
Text
Causes
Corrective Actions
book.book Page 31 Friday, November 20, 2009 2:56 PM
Summary of Contents for PowerEdge R510
Page 11: ...Contents 11 7 Getting Help 199 Contacting Dell 199 Glossary 201 Index 211 ...
Page 12: ...12 Contents ...
Page 82: ...82 Using the System Setup Program and UEFI Boot Manager ...
Page 188: ...188 Troubleshooting Your System ...
Page 198: ...198 Jumpers and Connectors ...
Page 200: ...200 Getting Help ...
Page 210: ...210 Glossary ...