EMERGENCY genset alarm
Configure > Parameters >
General name
TB de-load failure
Breakers > Tie breaker monitoring > De-load failure
Breaker de-load failure
Vector mismatch
Breakers > Tie breaker monitoring > Vector mismatch
Vector mismatch
TB opening failure
Breakers > Tie breaker monitoring > Opening failure
Breaker opening failure
TB closing failure
Breakers > Tie breaker monitoring > Closing failure
Breaker closing failure
TB position failure
Breakers > Tie breaker monitoring > Position failure
Breaker position failure
TB trip (external)
Breakers > Tie breaker monitoring > Tripped (external)
Breaker trip (external)
TB short circuit
Breakers > Tie breaker monitoring > Short circuit
Breaker short circuit
TB configuration failure
-
Breaker configuration failure
Generator phase sequence error Generator > AC setup > Phase sequence error
Phase sequence error
Busbar phase sequence error
Busbar > AC setup > Phase sequence error
Phase sequence error
9.9.5 AC alarms
More information
The
AC configuration and nominal settings
chapter describes AC alarms in general.
The following tables show where to configure these alarms for the EMERGENCY genset controller.
Table 9.12
Generator AC alarm names for the EMERGENCY genset controller
EMERGENCY genset alarm
Configure > Parameters >
General name
Generator over-voltage 1 or 2
Generator > Voltage protections > Over-voltage 1 or 2
Over-voltage
Generator under-voltage 1 or 2
Generator > Voltage protections > Under-voltage 1 or 2
Under-voltage
Generator voltage unbalance
Generator > Voltage protections > Voltage unbalance
Voltage unbalance
Generator over-current 1 or 2
Generator > Current protections > Over-current 1 or 2
Over-current
Fast over-current 1 or 2
Generator > Current protections > Fast over-current 1 or 2
Fast over-current
Current unbalance (average calc.)
Generator > Current protections > Current unbalance (average
calc.)
Current unbalance (average
calc.)
Current unbalance (nominal calc.)
Generator > Current protections > Current unbalance (nominal
calc.)
Current unbalance (nominal
calc.)
Inverse time over-current
Generator > Current protections > Inverse time over-current
Inverse time over-current
Stabilised differential current
Generator > Current protections > Stabilised differential current
Stabilised differential
current
High set differential current
Generator > Current protections > High set differential current
High set differential current
Generator over-frequency 1 or 2
Generator > Frequency protections > Over-frequency 1 or 2
Over-frequency
Generator under-frequency 1 or 2 Generator > Frequency protections > Under-frequency 1 or 2
Under-frequency
Overload 1 or 2
Generator > Power protections > Overload 1 or 2
Overload
Reverse power 1 or 2
Generator > Power protections > Reverse power 1 or 2
Reverse power
Reactive power export 1 or 2
Generator > Reactive power protections > Reactive power
export 1 or 2
Reactive power export
Reactive power import 1 or 2
Generator > Reactive power protections > Reactive power
import 1 or 2
Reactive power import