Smart Control
b. Setting up a
schedule
will run the script at the times that you schedule .The
schedule
for Smart Control is in the local time zone. Therefore, if you set it to
run at 12:00, this means 12:00 of whatever timezone the system is set to and
not GMT or UTC.
eqcli
sc
-
scname
>
schedule
schedule string
where
schedule string
is in the standard cron format, but with an
additional first column:
second:
0-59
minute:
0-59
hour:
0-23
day of month:
1-31
month:
1-12 (or names, see below)
day of week:
0-7 (0 or 7 is Sun, or use names below)
"Lists" are supported (using comma) but "steps" (generally
specified with a "/") are not supported.
White space (' ' or
\t) is a
column break. The parsing starts at the first non-
white-space character. If the wrong number of columns (not 6)
is parsed, parsing fails.
Day names:
Mon,Tue,Wed,Thu,Fri,Sat,Sun
Month names: Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep,
Oct, Nov, Dec
Note
- The schedule string must be enclosed in quotes. i.e.: "* 0,30 * * * Mon" would be translated as
'Every Monday, run this this every 30 seconds'.
Displaying Configured Smart Controls
To display existing Smart Controls enter the following:
eqcli >
show smart_control
Name Interval Schedule
Test_1 648000
Test_2 0 * * 1 2 Feb Mon
eqcli >
700
Copyright © 2014 Coyote Point Systems, A Subsidiary of Fortinet, Inc.
Summary of Contents for Equalizer GX Series
Page 18: ......
Page 32: ...Overview 32 Copyright 2014 Coyote Point Systems A Subsidiary of Fortinet Inc ...
Page 42: ......
Page 52: ......
Page 64: ......
Page 72: ......
Page 76: ......
Page 228: ......
Page 238: ......
Page 476: ......
Page 492: ......
Page 530: ......
Page 614: ......
Page 626: ......
Page 638: ......
Page 678: ......
Page 732: ...Using SNMP Traps 732 Copyright 2014 Coyote Point Systems A Subsidiary of Fortinet Inc ...
Page 754: ......
Page 790: ......
Page 804: ......
Page 842: ......
Page 866: ......