C200H AC Servo Manual
87
29
POS0
Internal Position
Command
Selection0
The corresponding relationship of the internal position
selection:
Position
Command
POS2
POS1
POS0
CTRG
Parameter
P1
0
0
0
↑
P4-2
P4-3
P2
0
0
1
↑
P4-5
P4-6
P3
0
1
0
↑
P4-8
P4-9
P4
0
1
1
↑
P4-11
P4-12
P5
1
0
0
↑
P4-14
P4-15
P6
1
0
1
↑
P4-17
P4-18
P7
1
1
0
↑
P4-20
P4-21
P8
1
1
1
↑
P4-23
P4-24
30
POS1
Internal Position
Command
Selection1
31
POS2
Internal Position
Command
Selection2
33
SHOM
Starting Origin
Regression
In internal position register mode,it needs to search
for origin. The signal turns on and starts searching for
the origin function( Refer to the setting of P4-34).
34
ORGP
Origin Of
Regression
In internal position register mode,it needs to search
for origin. The signal turns on and starts searching for
the origin function( Refer to the setting of P4-32).