C200H AC Servo Manual
104
No.
Alarm name
Running
state
Reason
Processing method
5
Drive
overheating
Appears
when the
drive was
running
1. Circuit board failure.
2. The temperature of the
driver is too high.
1. Reduce the temperature of
the driver.
2. Replace the servo driver.
6
Speed
amplification
Saturation
fault
Appears
during
motor
operation
1. The load is too large.
2. The motor is
mechanically stuck.
1. Reduce the load.
2. Replace the driver and
motor with higher power.
3. Check the mechanical part
of the load.
7
Drive inhibit
exception
The CCW / CW drive
inhibit input terminals are
disconnected.
Check the wiring.
8
Position
deviation
Counter
overflow
1. The motor is
mechanically stuck.
2. The input command pulse
is abnormal.
1. Check the mechanical part
of the load.
2. Check the command pulse.
3. Check whether the motor
rotates according to the
command pulse.