C200H AC Servo Manual
92
P4-4
The move
speed of
Internal
position
instruction 1
To set the move speed of internal position instruction 1.
0-5000
r/min
1000
P4-5
The number of
position cycles
of internal
position
instruction 2
To set the number of position cycles of the second
stage internal position.
-30000-
30000
0
P4-6
The pulse
number setting
in position loop
of internal
position
instruction 2
1. To set the position pulses of the second stage
internal position.
2.
Internal position instruction 2=the position
cycles setting of the second internal pthe
pulse number setting of the second internal position.
+/-max.
cnt/rev
0
P4-7
The move
speed of
internal
position
instruction 2
To set the move speed of internal position instruction 2.
0-5000
r/min
1000
P4-8
The position
cycles of
internal
position
instruction 3
To set the position cycles of the third stage internal
position instruction.
-30000-
30000
0
P4-9
The pulse
number setting
in position loop
of internal
position
instruction 3
1. To set the position pulses of the third stage
internal position.
2.
Internal position instruction 3=the position
cycles setting of the third internal pthe
pulse number setting of the third internal position.
+/-max.
cnt/rev
0
Summary of Contents for C200H Series
Page 1: ...https en coolmay com ...
Page 2: ...C200H AC Servo Manual https en coolmay com ...
Page 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Page 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Page 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...