C200H AC Servo Manual
22
4.4.4 Digital Quantity Input And Output Signal
Signal Name
Pin No.
Function
Introduction
Digital
Input
DI1
20
servo enable
Optocoupler input and function can be
programmable.Defined by parameter P3
group( P3-0~P3-17).
The input voltage of COM is both of
common positive and negative terminal.
And input signal voltage is 12~24V.
In position mode (internal position
mode) and non-position mode ,please
connect 24 V to pin 7, DI5 to pin21, DI6
to pin 22. Or to connect 0 V to pin7, DI5
to 5 pin ,DI6 to pin 6.
DI2
4
alarm clearance
DI3
19
CWdriveinhibition
DI4
3
CCW drive
inhibition
DI5
18
Forward external
torque limit
DI6
2
Reverse external
torque limit
DI7
17
Zero-speed clamp
DI8
1
Zero instruction
PULS-
21
In position mode
(internal position
mode) and
non-position mode
SIGN-
22
PULS+
5
SIGN+
6
PULLHI
7
COM
16
Common end of
digital input signals
Digital
Output
DO1+
31
Servo ready
Photo isolation output.Function can be
programmable.
Defined by parameter P3 group
( P3-20~P3-23).
DO1-
32
DO2+
33
Alarm output
DO2-
34
DO3+
35
Positioning
completion
DO3-
36
DO4+
37
Magnetic brake
DO4-
38
DO5+
39
Speed arrival
DO5-
40
DO6+
41
Torque arrival
DO6-
42
RS485
RSB
10
RS485
RS485 communication negative end
Summary of Contents for C200H Series
Page 1: ...https en coolmay com ...
Page 2: ...C200H AC Servo Manual https en coolmay com ...
Page 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Page 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Page 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...