C200H AC Servo Manual
74
No.
Name
Function
Rang
Default
Value
55
Effective
level
control
word of
input
terminals
1.To reverse the input terminals. For unreversed
terminals, it is valid when the switch is closed,
while it is invalid when the switch is open. For
reversed terminals, it is invalid when the switch is
closed, while it is valid when the switch is open.
2.Represented by a binary digit of 4 bits. If it is 0, it
means the input terminal dose not reverse. While it is
1, it means the terminal reverses.
The binary digit represents the input terminals as
following:
7
6
5
4
3
2
1
0
DI
8
DI
7
DI
6
DI
5
DI
4
DI
3
DI
2
DI
1
0: high level is active.
1: low level is active.
0000-11
11
0000
57
Effective
level
control
word of
output
terminals
1.To reverse the output terminals. For reversed
terminals,the definitions of breaking over and cut-off
is contrary to standard definitions
2.Represented by a binary digit of 4 bits. If it is 0, it
means the input terminal dose not reverse. While it is
1, it means the terminal reverses.
The binary digit represents the input terminals as
following:
5
4
3
2
1
0
DO6
DO5
DO4
DO3
DO2
DO1
0: high level is active.
1: low level is active.
0000-11
11
0000
58
Removing
jitter time
constant
of I/O
1.Set the removing jitter filter time for input terminal.
2.The value is smaller, the terminal input response
frequency is quicker.
3.The value is bigger, the anti-jamming performance
1-20ms
2
Summary of Contents for C200H Series
Page 1: ...https en coolmay com ...
Page 2: ...C200H AC Servo Manual https en coolmay com ...
Page 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Page 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Page 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...