6.7 How To Reset Default Parameters
To recover default parameters when:
●
The parameters are scrambled and the system can not work properly.
The steps to recover default parameters as follow:
1. Please connect the motor with the driver and power on. The driver will automatically read the
motor parameters and match the motor model.
2. Set password (PA0) to 385.
3. Do the followings:
Press the
key to return to the main menu and to select “
PA-
”with
or
key. Press
the
SET
key to enter into the second layer and press the
or
key to make PA=0.Then
press the
SET
key to enter into the third layer and set PA0 =385, pressing the
SET
key to save it.
Next, press the
key to return to the "
PA-
" and set the PA1=
DEF-
. L
ong press the
SET
key for 5 seconds and after the LED indicator lights flicker several times, the operation is
completed Finally, it will work after repower on.