C200H AC Servo Manual
46
5.2.3 Parameter Settings In Speed Mode
Parameter
Introduction
Range
Default Value
PA4
Control Mode
1
0
PA5
Speed Proportional Gain
5-2000Hz
150
PA6
Speed Integral Constant
1-1000ms
75
PA22
Internal And External Speed
Instruction Selection
0-5
0
PA24
Internal Speed 1
-6000-6000r/min
100
PA25
Internal Speed 2
-6000-6000r/min
500
PA26
Internal Speed 3
-6000-6000r/min
1000
PA27
Internal Speed4
-6000-6000r/min
2000
PA28
Arrival Speed
0-3000r/min
3000
PA40
Acceleration Time Constant
1-10000ms
100
PA41
Deceleration Time Constant
1-10000ms
100
PA42
S Type Acceleration And
Deceleration Time Constant
0-1000ms
0
PA43
Gain Of Analog Speed Command
10-3000r/min/v
300
PA44
Direction Of Analog Speed
Command
0-1
0
PA45
Zero Offset Compensation Of
Analog Speed Command
-5000-5000
0
PA46
Filter Of Analog Speed Command
1-300Hz
300
PA75
Zero-speed Detection Point
0-1000r/min
10
PA76
The Setting Value For Speed
Consistent
0-1000r/min
10
PA87
Hysteresis Of Arrival Speed
0-5000r/min
30
PA88
Polarity Of Arrival Speed
0-1
0
PA92
Hysteresis For Zero Speed
Detection
0-1000r/min
5
Summary of Contents for C200H Series
Page 1: ...https en coolmay com ...
Page 2: ...C200H AC Servo Manual https en coolmay com ...
Page 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Page 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Page 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...