C200H AC Servo Manual
67
No.
Name
Function
Rang
Default
Value
22
The source
of speed
command
In speed control mode, it sets the source of speed
command. It means:
0: Analog Terminal AS+,AS- input analog speed
command.
1:Internal speed command is decided by SP1 and
SP2 of digital input(DI):
DI Signal
Speed Command
SP2
SP1
0
0
Internal Speed1(PA24)
0
1
Internal Speed2(PA25)
1
0
Internal Speed2(PA26)
1
1
Internal Speed2(PA27)
Note: 1=ON, 0=OFF.
2: Analog speed internal speed command:
DI Signal
Speed Command
SP2
SP1
0
0
Analog Speed Command
0
1
Internal Speed2(PA25)
1
0
Internal Speed2(PA26)
1
1
Internal Speed2(PA27)
3: JOG speed command, if carries out JOG
operation,it is needed to set.
4: Keyboard speed command, if carries out Sr
operation,it needs to set the parameter.
5:IO terminal controls JOG operation.
0-5
0
23
Highest
speed limit
Set the highest speed of the ac motor.
1.It doesn’t matter with rotating direction.
2.If the setting value is beyond of rated speed, the
real highest speed is set as the rated speed.
0-6000r/m
in
5000