C200H AC Servo Manual
63
you need higher torque response frequency, it is
recommended to increase the setting value.
8
Speed
detection
filter
1. To set the characters of speed detection filter.
2. The value is smaller, the cut-off frequency is
lower and noise from the motor is smaller. If the
load inertia is great, reducing the setting value is
recommended. If the value is too small, it would
lead to low response, which would result in
shaking.
3.
The value is bigger, the cut-off frequency is
higher and the response frequency is quicker. If
you need higher torque response frequency, it is
recommended to increase the setting value.
20-500%
100
9
Proportional
gain of
position loop
1.To set the proportional gain of position loop .
2.The value is bigger, the gain is higher and its
rigidity is stronger. So the position lag is smaller
under the same frequency command pulse
condition. But if it is too big, it will happen
oscillation.
3.The parameter value is set according to your
exact servo driving system model and the load.
1-1000
80
10
Number of
pulses output
for each
motor
revolution
To set the number of pulses output by the encoderAB
phase for each motor revolution.
0-20000
10000
11
Command
pulses of
each motor
revolution
1.To set command pulses of each motor
revolution.
2.
When it is set to 0, PA12( numerator of
electronic gear for position command pulses),
PA13(denominator of electronic gear for position
command pulses) are valid.
0-30000
10000
Summary of Contents for C200H Series
Page 1: ...https en coolmay com ...
Page 2: ...C200H AC Servo Manual https en coolmay com ...
Page 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Page 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Page 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...