MC012C-BS00 UNITIZED TRANSAXLE WITH DIFFERENTIAL LOCK
Unitized Transaxle Installation
2006-2010 Turf/Carryall 272/472 and XRT 1200/1200 SE Maintenance and Service Manual
Page 16-21
16
28. Connect accelerator cable to actuator cam in the electrical box. Position the accelerator cable in mount-
ing slot in the wall of the electrical box and tighten mounting nuts to 18 in-lb (2.0 N·m)
. Install electrical box cover and tighten mounting screw to 18 in-lb (2.0 N·m).
29. Pull fuel line from impulse line fitting of the fuel pump and connect it to the carburetor and secure with a
hose clamp
30. Connect the impulse line to the fuel pump and secure it with the hose clamp
.
31. Connect air intake hose to carburetor and secure hose clamp
32. Connect carburetor vent tube to carburetor and secure with hose clamp
.
33. Connect the differential lock cable end to the differential lock handle.
33.1. Connect the end of the differential lock cable to the differential lock handle (Step 1)
33.2. Push down on the cable to secure the end of the cable to the differential lock handle (Step 2).
33.3. Rotate the cable counterclockwise to route the cable through the bracket (Step 3).
33.4. Push the cable sheath toward the front of the vehicle to secure the cable to the bracket
.
33.5. Secure the cable to the vertical support with a wire tie (6).
Figure 16-51 Connect Cable to Cam
Figure 16-52 Connect Fuel Line
Figure 16-53 Impulse Line
Figure 16-54 Air Intake Hose
TOP VIEW
ACCELERATOR CABLE
CLAMP
IMPULSE LINE
CLAMP
Summary of Contents for CARRYALL 272
Page 2: ......
Page 14: ......
Page 18: ...1...
Page 52: ...5...
Page 90: ...6...
Page 110: ...7...
Page 112: ...8...
Page 128: ...10...
Page 170: ...11...
Page 224: ...13...
Page 284: ...16...
Page 302: ...17...
Page 308: ......
Page 309: ...Club Car R NOTES...
Page 310: ...Club Car R NOTES...
Page 311: ......