CL-7
Operating Data:
Record the following information from the Run Status, Temperatures and Outputs Modes when machine is in a
stable operating condition.
TEMPERATURES
EVAPORATOR ENTERING FLUID _______________
EVAPORATOR LEAVING FLUID
_______________
CONTROL POINT
_______________
CAPACITY
_______________
OUTSIDE AIR TEMPERATURE
_______________
CHWS TEMPERATURE
_______________ (Dual Chiller Control Only)
CIRCUIT A CIRCUIT B
SATURATED COND TMP CIRC A
__________ SATURATED COND TMP CIRC B __________
SATURATED SUCTION TEMP A
__________ SATURATED SUCTION TEMP B __________
SATURATED LIQUID TMP A __________ SATURATED LIQUID TMP B __________
COMPRESSOR SUCTION TMP A
__________ COMPRESSOR SUCTION TMP B
__________
DISCHARGE GAS TEMP CIR A
__________ DISCHARGE GAS TEMP CIR B __________
MOTOR TEMPERATURE CIR A
__________ MOTOR TEMPERATURE CIR B __________
EXV ECO. TMP CIR A
__________ EXV ECO. TMP CIR B __________
LIQUID TEMPERATURE A __________ LIQUID TEMPERATURE B __________
COMPRESSOR MOTOR CURRENT
L1 L2 L3
COMPRESSOR A1_______ _______ _______
COMPRESSOR B1_______ _______ _______
CONDENSER FAN MOTOR CURRENT, STANDARD TIER UNITS
CONDENSER FAN MOTOR CURRENT, STANDARD TIER WITH LOW AMBIENT MID AND HIGH TIER
HEATER CURRENT
EVAPORATOR HEATER CURRENT
__________
OIL SEPARATOR HEATER CURRENT CIRCUIT A
__________
OIL SEPARATOR HEATER CURRENT CIRCUIT B
__________
L1
L2
L3
L1
L2
L3
FAN MOTOR A1
____ ____ ____ FAN MOTOR B1
____
____
____
FAN MOTOR A2
____ ____ ____ FAN MOTOR B2
____
____
____
FAN MOTOR A3
____ ____ ____ FAN MOTOR B3
____
____
____
FAN MOTOR A4
____ ____ ____ FAN MOTOR B4
____
____
____
FAN MOTOR A5
____ ____ ____ FAN MOTOR B5
____
____
____
FAN MOTOR A6
____ ____ ____ FAN MOTOR B6
____
____
____
FAN MOTOR A7
____ ____ ____ FAN MOTOR B7
____
____
____
FAN MOTOR A8
____ ____ ____ FAN MOTOR B8
____
____
____
FAN MOTOR A9
____ ____ ____ FAN MOTOR B9
____
____
____
FAN MOTOR A10
____ ____ ____ FAN MOTOR B10
____
____
____
FAN MOTOR A11
____ ____ ____ FAN MOTOR B11
____
____
____
FAN MOTOR A12
____ ____ ____ FAN MOTOR B12
____
____
____
Hz
A
VFD A1
____ ____
VFD A2
____ ____
VFD B1
____ ____
VFD B2
____ ____
Summary of Contents for AquaForce 30XV140
Page 79: ...79 Fig 76 VFD Communication Wiring Compressor A B Fan VFD A1 A2 B1 B2...
Page 228: ...228 Fig 90 30XV Typical Field Wiring Schematic cont...
Page 229: ...229 Fig 91 30XV Standard Tier 140 275 All Voltages Power Schematic NOTE See Legend on page 226...
Page 230: ...230 Fig 92 30XV Standard Tier 300 325 All Voltages Power Schematic NOTE See Legend on page 226...
Page 240: ...240 Fig 99 30XV Communication Wiring...
Page 241: ...241 Fig 100 30XV 115V Control Wiring All Tonnages All Voltages...
Page 242: ...242 Fig 101 30XV 24V Control Wiring 30XV140 325 All Voltages...
Page 243: ...243 Fig 101 30XV 24V Control Wiring 30XV140 325 All Voltages cont...
Page 244: ...244 Fig 102 30XV 24V Control Wiring 30XV350 500 All Voltages...
Page 245: ...245 Fig 102 30XV 24V Control Wiring 30XV350 500 All Voltages cont...
Page 246: ...246 Fig 103 Component Arrangement Diagram for 30XV140 325...
Page 247: ...247 Fig 103 Component Arrangement Diagram for 30XV140 325 cont...
Page 248: ...248 Fig 104 Component Arrangement Diagram for 30XV350 500...
Page 337: ...337 APPENDIX J FACTORY SUPPLIED PUMPS cont Fig L System Information...
Page 338: ...338 APPENDIX J FACTORY SUPPLIED PUMPS cont Fig M Unit and Language Settings...
Page 341: ...341 APPENDIX J FACTORY SUPPLIED PUMPS cont Fig P Data Input 2...
Page 342: ...342 APPENDIX J FACTORY SUPPLIED PUMPS cont Fig Q Data Input 3...
Page 347: ...347 APPENDIX J FACTORY SUPPLIED PUMPS cont Fig U Pump Wiring Diagram...