COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 SELF DIAGNOSIS
6-19 T
E5F3
Main Cause
The alignment home position sensor (PI5S) is faulty. The alignment motor
(M5S) is faulty. The saddle stitcher controller PCB is faulty.
Mode of
Detection
0001 The alignment plate home position sensor does not turn on when
the alignment motor has been driven for 0.5 sec (initially, driven
for about 1.7 sec).
0002 The alignment plate home position sensor does not turn off when
the alignment motor has been driven for 1 sec.
E5F4
Main Cause
The stitch home position sensor (rear, MS5S) is faulty. The stitch motor
(rear, M6S) is faulty. The saddle stitcher controller PCB is faulty.
Mode of
Detection
0001 The stitcher home position sensor (rear) does not turn off when the
stitch motor (rear) has been rotated CW for 0.5 sec or more.
0002 The stitch home position sensor (rear) does not turn on when the
stitch motor (rear) has been rotated CCW for 0.5 sec or more.
E5F5
Main Cause
The stitch home position senor (front, MS7S) is faulty. The stitch motor
(front, M7S) is faulty. The saddle stitcher controller PCB is faulty.
Mode of
Detection
0001 The stitch home position sensor (front) does not turn off when the
stitch motor (front) has been rotated CW for 0.5 sec or more.
0002 The stitch home position sensor (front) does not turn on when the
stitch motor (front) has been rotated CCW for 0.5 sec or more.