COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 SERVICE MODE
5-53 T
COPIER>ADJUST
H-PRE-TR
Use it to enter the offset value for the pre-transfer high-voltage output of
the DC controller PCB.
Caution
If you have replaced the DC controller PCB or cleared the RAM on the DC
controller PCB, enter the settings indicated on the label attached to the new
DC controller PCB.
D-PRE-TR
Use it to enter the offset value for the pre-transfer high-voltage output of
the DC controller PCB.
Caution
If you have replaced the DC controller PCB or cleared the RAM on the DC
controller PCB, enter the settings indicated on the label attached to the new
DC controller PCB.
D-HV-TR
Use it to enter the offset value for the transfer high-voltage output of the
DC controller PCB.
Caution
If you have replaced the DC controller PCB or cleared the RAM on the DC
controller PCB, enter the settings indicated on the label attached to the new
DC controller PCB.
<HV-SP>
Adjusting the Output of the Separation Charging Assembly
SP-N1
Use it to enter the output adjustment value of the separation charging cur-
rent (printing on the face of a sheet of plain paper and printing on the 1st
side of a double-sided sheet).
Caution
If you have cleared the RAM on the DC controller PCB, enter the settings
indicated on the service label.
SP-N2
Use it to enter the output adjustment value of the separation charging cur-
rent (printing on the 2nd side of a double-sided sheet of plain paper).
Caution
If you have cleared the RAM on the DC controller PCB, enter the settings
indicated on the service label.
HVT-SP
Use it to enter the offset value for the separation high-voltage output of the
high-voltage unit.
Caution
If you have replaced the high-voltage unit or cleared the RAM on the DC
controller PCB, enter the settings indicated on the label attached to the new
high-voltage unit.