COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 6 FIXING SYSTEM
6-22 P
[3]
[2]
[1]
[5]
[5]
[5]
[4]
[4]
[6]
4.1.2 Removing the Fixing Assembly
1) Slide out the fixing/feeding unit.
2) Remove the three screws [1] and the
knob [2]; then, detach the fixing/feeding
left cover [3].
F06-401-03
3) Disconnect the two connectors [4], and
remove the three screws [5]; then, de-
tach the fixing drive assembly [6].
F06-401-04
4) Disconnect the three connectors [7], and
free the harness from the harness guide.
F06-401-05
[7]
[7]