4.7.4 Removing the External Delivery Sensor
1) Remove the fixing/feeding unit from the
machine.
2) Remove the external delivery roller.
3) Remove the two sensors [1], and detach
the sensor support plate [2].
F06-407-07
4) Disconnect the connector [3], and de-
tach the external delivery sensor [4].
F06-407-08
[2]
[1]
[4]
[3]