CHAPTER 4 IMAGE FORMATION SYSTEM
4-76 P
5) Remove the two mounting screws [7],
and detach the electrode plate [8].
F04-709-07
6) Remove the mounting screw [9], and
detach the magnetic positioning plate
[10].
F04-709-08
7) Remove the grip ring [11] mounted to
the cylinder shaft at the front, and de-
tach the push-on roll [12].
F04-709-09
[8]
[7]
[10]
[9]
[11]
[12]