2-12 General Description
STATUS LED
indication
Description Procedure
On (green)
The server is operating normally.
–
Flashing
(green)
•
The server is operating with the
memory or CPU in degraded
state.
•
An uncorrectable memory error
has often occurred.
Identify the device in degraded state by using the BIOS setup
utility "SETUP," and replace it as soon as possible.
The power is off.
–
POST is in progress.
Wait for a while. The STATUS LED turns green when POST is
completed.
A CPU error occurred. (IERR)
A CPU temperature alarm was
detected.
A timeout occurred when the time
set for the watchdog timer arrived.
A CPU bus error occurred.
Turn the power off and then turn it on. If the POST screen displays
an error message, take notes of the message, and contact your
sales representative.
Off
A memory dump request is made.
Wait until the memory dump is completed.
A temperature alarm was detected.
Check if the internal fans are clean and if the fan units are firmly
connected.
If the STATUS LED indication does not change when the fans are
normal, contact your sales representative.
A voltage alarm was detected.
All the power supply units failed.
On (amber)
A temperature alarm was detected
on chipset.
Contact your sales representative.
Flashing
(amber)
Either of the following was detected
in the redundant power
configuration:
•
AC power not supplied to one of
the two power supply units
•
Failure of one of the two power
supply units
Connect the power cord to supply power. If the power supply unit
is faulty, contact your service representative.
A fan alarm was detected.
Check if the fan units are firmly connected.
If the STATUS LED indication does not change when the fans are
normal, contact your sales representative.
A temperature warning was
detected.
Check if the internal fans are clean and if the fan units are firmly
connected.
If the STATUS LED indication does not change when the fans are
normal, contact your sales representative.
A voltage warning was detected
Contact your service representative.
An error was detected on either of
the hard disk drives.
Detected that the top cover is open.
Check if the top cover is open or not.
Summary of Contents for NovaScale R460 E2
Page 1: ...NovaScale R460 E2 User s Guide NOVASCALE REFERENCE 86 A1 47FB 00...
Page 2: ......
Page 8: ......
Page 21: ...Notes on Using Your Server 1 3 Internal View...
Page 34: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Page 392: ...9 96 Upgrading Your Server This page is intentionally left blank...
Page 402: ......
Page 404: ...C 2 IRQ This page is intentionally left blank...
Page 429: ...Installing Windows Server 2008 D 25 4 Activate Windows The Windows activation is complete...
Page 456: ......
Page 482: ...G 2 Using a Client Computer which has a CD Drive This page is intentionally left blank...
Page 486: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 489: ......
Page 490: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...