8-12 Troubleshooting
Messages displayed on lower line (BMC message)
When the following messages are displayed on the virtual LCD, restart your server by turning off and on. If an error still
occurred, contact your service representative for maintenance.
On-screen message
Description
240VA Power Down
Power supply failure occurred.
BB +1.5v Alm XX
BB +1.8v Alm XX
BB 1.8vsb Alm XX
BB +3.3v Alm XX
BB 3.3vsb Alm XX
BB +5.0v Alm XX
BB 5vsb Alm XX
BB +12v Alm XX
Processor1 P_Vtt Alm XX
Processor2 P_Vtt Alm XX
Processor1 1.5v Alm XX
Processor2 1.5v Alm XX
Baseboard 1.0vsb Alm XX
Baseboard 1.1v Alm XX
Baseboard 1.2vsb Alm XX
Voltage alarm occurred on the mother board.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
BB Temp1 Alm XX
Mother board thermal error occurred.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
DUMP Request !
Dump switch is pressed.
OS shutdown Alm
OS shutdown alarm occurred.
Power On Cnt Alm
Power supply failure occurred.
Power Unit 1 Alm
Power unit #1 Failure occurred.
Power Unit 2 Alm
Power unit #2 Failure occurred.
Proc Missing
Processor is not found.
Proc 1 T-Trip
Proc 2 T-Trip
Thermal Trip occurred on processor #1 or #2. The system is forcibly turned off.
Proc1 Therm % XX
Proc2 Therm % XX
CPU1_DIMM1 Tmp XX
CPU1_DIMM2 Tmp XX
CPU1_DIMM3 Tmp XX
CPU1_DIMM4 Tmp XX
CPU1_DIMM5 Tmp XX
CPU1_DIMM6 Tmp XX
CPU2_DIMM1 Tmp XX
CPU2_DIMM2 Tmp XX
CPU2_DIMM3 Tmp XX
CPU2_DIMM4 Tmp XX
CPU2_DIMM5 Tmp XX
CPU2_DIMM6 Tmp XX
FP Temp Alm XX
Processor #1 or #2 thermal error occurred.
XX=09: high temperature (fetal)
XX=07: high temperature (warning)
XX=02: low temperature (warning)
XX=00: low temperature (fetal)
Proc1 VccpAlm XX
Proc2 VccpAlm XX
Voltage alarm occurred on processor #1 or #2.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
ChipSet T-Trip
Forcedly powered off due to temperature alarm on chipset.
CPU1_DIMM U-Err
Unrecoverable error occurred on one of DIMMs on CPU1 side.
CPU2_DIMM U-Err
Unrecoverable error occurred on one of DIMMs on CPU2 side.
Processor 1 IERR
IERR occurred on processor #1 or #2.
Summary of Contents for NovaScale R460 E2
Page 1: ...NovaScale R460 E2 User s Guide NOVASCALE REFERENCE 86 A1 47FB 00...
Page 2: ......
Page 8: ......
Page 21: ...Notes on Using Your Server 1 3 Internal View...
Page 34: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Page 392: ...9 96 Upgrading Your Server This page is intentionally left blank...
Page 402: ......
Page 404: ...C 2 IRQ This page is intentionally left blank...
Page 429: ...Installing Windows Server 2008 D 25 4 Activate Windows The Windows activation is complete...
Page 456: ......
Page 482: ...G 2 Using a Client Computer which has a CD Drive This page is intentionally left blank...
Page 486: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 489: ......
Page 490: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...