For connection of Sanyo Denki absolute encoders to the NYCe 4000, you
can use encoder cable RKG0040, order number R911328668, see
"Sanyo Denki absolute encoder cable layout" on page 185
. This cable is
custom made to the length specified.
fig. 13-22 "Sanyo Denki absolute
encoder cable pinout" on page 185
shows the cable pinout. The mentioned
colors at the left side are the colors of the Sanyo Denki encoder wires.
Fig. 13-21:
Sanyo Denki absolute encoder cable layout
Enc5V
EncGND
Dig5VIn#c+
Dig5VIn#c-
ES+
ES-
Sanyo Denki
encoder cable
RD
BK
BN
BE
PK
PE
Shield
Fig. 13-22:
Sanyo Denki absolute encoder cable pinout
For proper use, you can choose between two voltage sources to connect to
/Battery–.
●
3.6 V battery: the encoder always returns an absolute position, even
when system power is switched off.
●
Enc5V: the encoder works properly, but when system power is switched
off, the absolute position is lost.
Follow these cabling instructions.
●
Always use a shielded cable.
●
The shielding on the NYCe 4000 side of the cable must be connected to
Shield (house connector).
●
If the equipment on the application side is metal, connect the shield to
the equipment housing.
NYCe 4000 Multi-axis motion control system Hardware Sys‐