IndraDrive
IndraDrive
IndraDrive
NY4150
RKB001x
RKB001x
RKB001x
RKB001x
DRV NET
PORT1
PORT2
Fig. 12-6:
Connection ring between NY4150 and IndraDrive(s)
The type numbers of the cables between the NY4150 and the IndraDrive(s)
are the following.
●
RKB0013, which have a length of 25, 35 or 55 cm.
●
RKB0011, length is specified by the customer.
The RKB0013 is in principle meant for connection of IndraDrives that are
installed next to each other. The RKB0011 is meant to span larger distances.
The RKB0011 and RKB0013 are electrically identical.
12.10 Installation requirements
Damage to components may occur if power
is applied during installation or removal.
WARNING
●
Make sure power supplies are switched off before installation or removal
of the NY4150 module.
●
Do not apply power until the NY4150 module is installed.
Damage to components may occur due to
electrostatic discharges.
WARNING
●
Comply with all ESD protective measures while working with modules
and components. Avoid electrostatic discharges.
The RJ45 connections to the SERCOS network are located on the front of
the NY4150 module. Some form of network cable strain relief is required for
this type of connection to ensure a reliable contact between the RJ45 plug
and header. You can use the NY4901/10 cable strain relief bracket installed
on the NY4112 or NY4114 MCU, or the NY4901/40 cable strain relief bracket
154/233
NY4150 and NY4150/10: SERCOS III Master Module
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual