5.3
Module dimensions
Fig. 5-3:
NY4110 module dimensions
Module type code
Width
Height
Depth
Weight
NYM04.1-MCU-NNNN-NY4110
21.8 mm
128.4 mm 148.5 mm 350 gr
Tab. 5-2:
NY4110 physical data
5.4
Field Diagnostics
The module does not contain any replaceable or wear parts. In case of
failure, the entire module must be replaced.
The NY4110 module has 2 bi-color module status indicator LEDs on the front
panel labeled "MCU" at the left side and "NET" at the right side.
●
"MCU" – Module status indicator
●
"NET" – IEEE 1394b network status indicator
The indications of the status indicator LEDs are described in
status LED indications" on page 31
.
LED indication (visible color)
Description
Green flashing
POST (Power On Self Test) in progress.
Green continuously
Result of POST is OK.
Node initialization successfully completed.
Orange continuously
Initializing node.
Red flashing
Start-up failure.
Red continuously
Result of POST is ERROR.
Tab. 5-3:
"MCU" status LED indications
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
31/233
NY4110: MCU Module
R911337671_Edition 18 Bosch Rexroth AG