11.14.3 Connection information
Characteristic
Description
Cable length
max 15 m.
Current capability
Conform application
Capacitance
max 100 pF/m.
Tab. 11-15:
Motor cable characteristics
The motor is connected to the drive according to
connections NY4140" on page 145
tab. 11-16 "Motor connections" on
.
2.2uF
Node
HB2
HB1
HB3
DP_PWR
DP_GND
Current
measurement
Current
measurement
Shortcircuit
detection
[See Note 3]
[See Note 5]
[See Note 4]
Drive
Power
Supply
Node
N
U
W
V
[See Note 3]
M
DR_PWR
DR_GND
filter
filter
3 x
1.2 µH
1 nF
3 x
500 V
3 x
15 W
Fig. 11-16:
Motor connections NY4140
Notes
1. Follow this cabling instruction:
Shielded cable is recommended, but not mandatory.
If shielded cable is used, the shielding on the NYCe 4000 side of the
cable must be connected to Shield (house connector).
Connect the other side to a convenient metal part or leave it open.
2. Connect the DR_GND of the drive power to the housing and/or safety
earth (if this is not already the case).
3. Connect the NYCe 4000, a power supply or other equipment on a metal
frame or mounting base and make sure there is a galvanic contact.
4. A fuse must be installed between the +V of the drive power supply and
DP_PWR on the node. The fuse is mandatory by safety regulations and
must be UL recognized. See NYCe 4000 Standard Housings and
Accessories manual for detailed information about fuses.
5. Connect an external capacitor close to the drive module (see
16.1 "Drive Power Filtering for NY412x/NY4140" on page 213
), in
order to avoid ripple currents.
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
145/233
NY4140: High Voltage Drive Module