17
Environmental Conditions
17.1
Thermal
Operating
●
Temperature : +5 °C … +55 °C
●
Relative Humidity : 10% … 90% (non-condensing)
Storage
●
Temperature : –40 °C … +85 °C (power derating applies, see
17.5 "Derating Conditions" on page 218
).
●
Relative humidity : 5% … 95% (non-condensing)
Thermal compatibility
●
Cold: EN 60068-2-1:2007
●
Dry heat: EN 60068-2-2:2007
●
Change of temperature: EN 60068-2-14:2009
●
Damp heat: EN 60068-2-30:2005
17.2
Shock and Vibration
Mechanical: Non-operating
●
Shock: IEC 60068-2-27:2008
Mechanical: Operating
●
Vibration: IEC 60068-2-6:2007
●
Vibration, broad-band: IEC 60068-2-64:2008
17.3
Electromagnetic Compatibility
Emission
Standard IEC 61000-6-4:2018 is met.
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments.
Immunity
Standard IEC 61000-6-2:2005 is met.
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity
for industrial environments.
●
Electrostatic discharge: EN 61000-4-2:2008
●
Radiated, RF electromagnetic field: IEC 61000-4-3:2020
●
Electrical fast transient (burst): IEC 61000-4-4:2012
●
RF conducted disturbances: IEC 61000-4-6:2013
17.4
Environment
Pollution degree (operating / storage and transport): 2.
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
217/233
Environmental Conditions
R911337671_Edition 18 Bosch Rexroth AG