224
FSN Series • User’s Guide
5. Menu Orientation
System Menu
qJ_~êI=gçóëíáÅâ=~åÇ=håçÄë
From the
Diagnostics Menu
, press
{T-Bar Joystick Knobs}
to display the
T-Bar,
Joystick, Knobs Menu
. The figure below illustrates a sample menu.
Figure 5-111.
T-Bar, Joystick, Knobs Menu (sample)
The
T-Bar, Joystick, Knobs Menu
enables you to perform diagnostic tests on the
T-Bar
,
Joystick
and the four knobs. The two tables at the top provide
Joystick
and
T-Bar
data.
•
Joystick
Table
— data is listed for the
X
,
Y
and
Z
axes. As you move the
Joystick
to its maximum limit along each axis, the proper range is
-100%
to
100%
. If the
Joystick
does not reach these values, or does not display
0%
when
fully at rest, use the
{Re-center}
button. See below for details.
•
T-Bar
Table
— data is listed for each bank’s
T-Bar
. As you move each
T-Bar
to
its top and bottom limits, the proper range is
0
to
100
. If the
T-Bar
does not
display these values at each limit, use the
{Set Top Limit}
and
{Set Bottom
Limit}
buttons. See below for details.
The following diagnostic functions are provided on the menu:
•
Knobs
— one data field is provided for each knob. As you rotate a knob, the
associated value should range between
+ 7
and
-7
, as you rotate the knob
clockwise and counter-clockwise, respectively.
T-Bar
Joystick
Knobs