www.baldormotion.com
6-4 Preset Moves & PLC Task
MN1901
6.2.3.1 Configuring digital inputs to control presets
The default combination of digital inputs used for triggering presets is 6, 7, 0 and 1 to select
the preset, and 5 to trigger the preset. However, this combination can be changed to use any
four (or fewer) contiguous inputs, plus a trigger input. The inputs form a bit pattern that
represents the preset to be selected. Consequently, if the application requires only a small
number of different preset moves, you can reduce the number of inputs required to select the
preset.
The following table shows the combinations of digital inputs that must be active to trigger each
preset index move. The table shows 4 inputs being used (0 - 3), allowing 16 presets to be
selected:
Preset index
(Bit pattern
sum)
Digital input 0
(Bit pattern
value: 1)
Digital input 1
(Bit pattern
value: 2)
Digital input 2
(Bit pattern
value: 4)
Digital input 3
(Bit pattern
value: 8)
0
0
0
0
0
1
1
0
0
0
2
0
1
0
0
3
1
1
0
0
4
0
0
1
0
5
1
0
1
0
6
0
1
1
0
7
1
1
1
0
8
0
0
0
1
9
1
0
0
1
10
0
1
0
1
11
1
1
0
1
12
0
0
1
1
13
1
0
1
1
14
0
1
1
1
15
1
1
1
1
Table 3 - Preset selection using digital inputs 0-3
For example, to select preset move 6, digital inputs 1 and 2 must be active. The choice of
digital inputs is configured using the Digital I/O tool:
1. In the Toolbox, click
Setup
then click the
Digital I/O icon.
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......