Basic Installation 3-35
MN1901
3.9.6 Switches 9 and 10 - RS232/RS485 select
Switch 9 is reserved for Baldor keypad selection.
Switch 10 selects RS232 communications (Off) or RS485/RS422 (On) the next time the
MintDrive
II
is power-cycled.
3.9.7 Factory settings
If switches 1-4 are all in the On position and switch 8 is set to Off, the MintDrive
II
will be reset to
its preset factory settings at power on (or whenever the processor is reset by WorkBench v5).
CAUTION
: Use this function carefully - it will erase your drive setup information.
When using the SW1 DIP switches to reset the MintDrive
II
to its factory defaults, all
parameters including the node number and serial communications baud rate will be reset. In
WorkBench v5, this means it will be necessary to rescan for the MintDrive
II
(by starting a new
project) to enable communication. It will also be necessary to re-tune your motor and drive.
On
1
Reapply
power.
1.
2.
On
2
On
3
On
4
MintDrive
II
will
be reset to its
preset factory
settings.
3.
Off
8
Remove
power.
4.
Figure 22 - Resetting the MintDrive
II
to its factory default settings
The Mint keyword
FACTORYDEFAULTS
can also be used to reset the MintDrive
II
to its factory
defaults. However, it will not reset the node number or serial communications baud rate. See
the Mint help file for details.
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......