www.baldormotion.com
CE Guidelines D-5
MN1901
D.1.6 Wiring of shielded (screened) cables
Remove the outer insulation
to expose the overall shield.
Clamp should provide 360°
contact with the cable.
or
Flat or p-type
conductive
clamp
Figure 59 - Earthing/grounding cable shields
Cable
1
6
2
7
3
8
MintDrive
II
X8
Twisted pairs
Resolver Connector
Housing
5
Connect overall shield
to connector backshell.
Connect overall shield
to connector backshell.
REF+
REF-
COS+
COS-
SIN+
SIN-
AGND
Figure 60 - Resolver cable grounding
1
6
2
7
3
8
11
13
MintDrive
II
X8
Encoder Connector
Housing
Cable
Twisted pairs
Connect overall shield
to connector backshell.
Connect overall shield
to connector backshell.
CHA+
CHA-
CHB+
CHB-
CHZ+
CHZ-
+5V
DGND
Figure 61 - Encoder signal cable grounding
1
6
2
7
3
8
5
MintDrive
II
X9
Auxiliary Encoder
Housing
Cable
Twisted pairs
9
Connect overall shield
to connector backshell.
Connect overall shield
to connector backshell.
CHA+
CHA-
CHB+
CHB-
CHZ+
CHZ-
+5V
DGND
Figure 62 - Auxiliary Encoder cable grounding
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......