www.baldormotion.com
Basic Installation 3-5
MN1901
H
For effective cooling and maintenance, the MintDrive
II
should be mounted on a smooth,
non-flammable vertical surface. The power handling capability is affected by the
temperature of the left side of the unit.
H
At least 50mm (2 in) top and bottom clearance of the MintDrive
II
must be provided for
airflow.
H
If multiple MintDrive
II
are being mounted side by side there must be 13mm (0.5 in)
between them. The MintDrive
II
nearest the side of the cabinet / enclosure must be
separated from it by at least 13mm (0.5 in).
H
To comply with CE directive 89/336/EEC an appropriate AC filter must be installed. The
external customer supplied 24VDC logic supply might also require a 24V filter. See section
3.4.7.
H
The threaded holes in the top and bottom of the enclosure are for cable clamps. The holes
are threaded for M4 bolts no longer than 12mm (0.47 in) in length. Longer bolts may short
circuit the electrical components inside the MintDrive
II
.
H
Each D-type connector on the front panel of the MintDrive
II
is secured using two
hexagonal jack screws (sometimes known as “screwlocks”). If a jack screw is removed
accidentally or lost it must be replaced with an identical jack screw with an external male
threaded section of 5mm (0.2 in). Jack screws with longer threads could damage or short
circuit internal components.
3.2.1 Mounting the MintDrive
II
Ensure you have read and understood the
Mechanical installation and location requirements
in
section 3.2. Mount the MintDrive
II
on its rear side, the side opposite to the front panel.
The MintDrive
II
must be mounted upright to ensure adequate cooling (you can check this by
ensuring that the Hazardous Voltages warning information is clearly readable to you).
M5 bolts or screws should be used to mount the MintDrive
II
.
There are seven different package sizes depending on the specification of the MintDrive
II
:
AC power
Current
Factory fitted option
Package size
Single-phase
2A
without option
A
with option
B
5A
without option
C
with option
D
7.5A
without option
D
with option
D
230V
Three-phase
15A
with or without option
E
230-460V
Three phase
2.5A, 5A, 7.5A
with or without option
G
Three-phase
15A, 20A, 27.5A
with or without option
H
Detailed dimensions for each package are shown in section 3.2.2.
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......