www.baldormotion.com
Basic Installation 3-15
MN1901
3.5 Motor connections
The motor can be connected directly to the MintDrive
II
or through a motor contactor
(M-Contactor).
Location
Connector X1 / X1A
Part number
MDH
1
A...
MDH
2
A...
MDH
2
A
15
...
MDH
4
A...
Nominal output voltage
160VDC
320VDC
320VDC
565/650V
Output voltage range
135-176VDC
306-350VDC
258-355VDC
254-746VDC
See
section
3.5.5
V
W
U
Motor
To earth/ground outer shield, use 360° clamps connected to backplane
Thermal
switch
A
B
Brake
(if present)
C
D
See
section
3.5.6
Unshielded
lengths should be
as short as
possible.
Optional motor
circuit contactors
Figure 7 - Motor connections
CAUTION
: Do not connect supply power to the MintDrive
II
UVW outputs.
The MintDrive
II
might be damaged.
CAUTION
: The motor leads U, V and W must be connected to their corresponding U,
V or W terminal on the motor. Misconnection could result in uncontrolled
motor movement.
The motor power cable must be shielded for CE compliance. The connector or gland used at
the motor must provide 360 degree shielding. The maximum recommended cable length is
30.5m (100ft).
Note:
For CE compliance the motor earth/ground should be connected to the drive
earth/ground.
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......