www.baldormotion.com
Troubleshooting 7-5
MN1901
7.2.2 DB On (Regeneration) LED
The front panel
DB On
LED indicates regeneration activity.
Yellow
Power is being dissipated into the regeneration resistor
Off
No regeneration is occurring.
7.2.3 Communication
Problem
Check
Status display is
blank
Check that the customer supplied 24VDC power supply is connected
correctly to connector X1 and is switched on.
On models with an internally generated 24VDC supply, check that the
AC power supply is connected correctly to connector X1 and is
switched on.
WorkBench v5 fails
to detect the
MintDrive
II
- it
detects “No
controller found.
Communication
fault on COM
x
”.
Ensure that the MintDrive
II
is powered and the Status display is
illuminated (see section 7.2).
Check that the serial cable is connected between the PC’s COM port
and connector X6 on the MintDrive
II
.
Check which PC COM port is being used, or use the “Scan all serial
ports” option to locate the MintDrive
II
.
Check the wiring of the serial cable or try an alternate cable. Check
that DIP switch 10 (RS232/RS422) is set correctly (see section 3.9.6).
On the PC, try an alternative COM port.
Confirm that a mouse driver or other serial device is not conflicting
(using the same COM port) as WorkBench v5.
Does the MintDrive
II
have firmware in it? If you tried to download new
firmware and the download failed, the controller may not have
firmware. If this has happened, the Status display will show a minus
sign (-) and flash the decimal point repeatedly.
Check that the selected Baud rate is supported by the PC and
MintDrive
II
.
If the “Only scan COM
x
” option is selected in WorkBench v5, check
that the correct COM port is selected.
If the “Search up to Node
xx
“ option is selected in WorkBench v5,
check that the MintDrive
II
node number is not higher than this value.
Do you have multiple nodes on the bus? If so, they must all be set to
the same Baud rate. WorkBench v5 scans through all the node Id’s at
different Baud rates. When it finds a node, it will only continue to scan
for other nodes at the same Baud rate.
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......