5-8 Operation
MN1901
5.2.6 Performing a test move
This section tests the basic operation of the drive and motor.
1. Check that the Drive enable button is
pressed (down).
2. In the Toolbox, click the Edit & Debug icon.
3. Click in the Command window.
4. Type:
JOG.0 = 10
This will cause the motor to move
continuously at 10 units per second. In
WorkBench v5, look at the Spy window
located on the right of the screen. The Spy
window’s Velocity display should show 10
(approximately). If there seems to be very little motor movement, it is probably due to the scale
factor. In the Commissioning Wizard, on the Position Control page, if you did
not
adjust the
scale factor then the current unit of movement is feedback counts per second. Depending on
the motor’s feedback device, 10 feedback counts per second could equate to a very small
velocity. Issue another
JOG
command using a larger value, or use the Operating Mode Wizard
to select a suitable scale factor (e.g. 4000 if the motor has a 1000 line encoder, or 10,000 for
a 2500 line encoder).
5. To stop the test, type:
STOP.0
Summary of Contents for MDH1A05TB-RC23
Page 1: ...MintDriveII Servo Position Control SERVO DRIVE Installation Manual 01 07 MN1901...
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1901...
Page 94: ...www baldormotion com 6 10 Preset Moves PLC Task MN1901...
Page 122: ...www baldormotion com A 10 Accessories MN1901...
Page 130: ...www baldormotion com B 8 Control System MN1901...
Page 158: ...www baldormotion com D 6 CE Guidelines MN1901...
Page 164: ...www baldormotion com Comments MN1901 Thank you for taking the time to help us...
Page 165: ......