Trouble shooting 25
OUTDOOR UNIT
OUTDOOR UNIT
Error Method:
Error Method:
COMPRESSOR ROTOR LOCATION
DETECTION ABNORMAL
Detective Actuators:
Detective Actuators:
Control PCB detection circuit
Detective details:
Detective details:
When the location error of compressor is detected,the compressor is
stopped.(Abnormal Stop) It restarts upon the balance pressure control
(3 min.ST), and if the location error is detected with in 40 seconds again,
it stop again. If it is repeated for 4 Times (5
th
time abnormal stop), the
compressor becomes permanent stop. Then LED indicates Error and the
error information is output to the network
Forecast of Cause
Forecast of Cause:
1. Connection of electrical parts
4. Check Control PCB
2. Compressor defective
3. TR PWB ASSY defective
Check Point 3 : Diagnosis of TW PWB ASSY
Check Point 3 : Diagnosis of TW PWB ASSY
1.If error appears during the compressor running, check if each voltage between U – V,V – W, W – U are output in a good valance.
If the voltage value comparison between each terminal is abnormal when the rotation frequency is constant, replace
TW PWB ASSY.
2. Check TR ASSY(Judgment of Transistor module)
Check the continuity by removing each terminal cable.
Replace TR ASSY if it is abnormal.(Compare with the table on right)
Check Point 1 :
Check Point 1 :
Check the electrical parts connection
Check the electrical parts connection
Check the connection of CN15,16 between TR PWB ASSY and Control PCB
Check if incorrect wiring is done at the U,V,W terminal between TR PWB ASSY and Compressor
If abnormal connection is found, correct the connection.
P
U
V
W
N
TR PWB ASSY
(+),( - ) shows the terminal of the meter
Outdoor unit grille side
Check Point 2 :
Check Point 2 :
Check Compressor
Check Compressor
Check motor Coil
1.Check the continuity between each terminals of coil U, V, W (resistance value : 0.187 )
2.Check if there is a cut off between each terminals of U,V,W
If the resistance value is abnormal or open, the compressor is defective
Check Point 3 : Check Control PCB (Location Detector Circuit)
Check Point 3 : Check Control PCB (Location Detector Circuit)
Remove CN14 connector on Control PCB, and check the voltage DC5.0V between 1-2.
Replace Control PCB if the voltage is 0V.
Indicate or Display:
Indicate or Display:
Indoor Unit :
Operation LED
Flash
Flash
,
,
Timer LED
3 Times Blink
3 Times Blink
Swing LED
3 Times Blink
3 Times Blink
Outdoor Unit :
LED1
Flash
Flash
,
,
LED4
9
4 Times Blink
ERROR CODE: E:32
14 15
N ( )
N ( )
W ( )
V ( )
14 15
U ( )
P ( )
V ( )
U ( )
W ( )
V ( )
U ( )
P ( )
W ( )
V ( )
U ( )
W ( )
Normal
resistance
value
COMP
TERMINAL
P / N
TERMINAL
06-28
Multimeter
Resistance value
U
1M Ohm or greater
U
W
V
P
W
V
N
The resistance value is changes in a type
of the tester (Digital or Analogue)
and internal resistance.
Confirm method for analog meter.
Simple confirm method for digital meter.
Summary of Contents for AO54FJ
Page 5: ...1 TEST RUN TM SERIES R410A ...
Page 14: ...2 FUNCTION OF PRINTED CIRCUIT BOARD TM SERIES R410A ...
Page 39: ...3 INVERTER CONTROL TM SERIES R410A ...
Page 45: ...4 OUTDOOR UNIT OPERATION CONTROL TM SERIES R410A ...
Page 54: ...5 INDOOR UNIT OPERATION TM SERIES R410A ...
Page 70: ...6 TROUBLE SHOOTING TM SERIES R410A ...
Page 128: ...7 INSTALLATION TM SERIES R410A ...
Page 140: ...8 REFRIGERANT CAUTION R410A TM SERIES R410A ...
Page 149: ...9 APPENDING DATA1 UNIT TM SERIES R410A ...
Page 156: ...LOW STATIC PRESSURE DUCT TYPE MODELS AR25 AR30 ARXB25 ARXB30 09 07 ...
Page 157: ...MODELS AR36 AR45 09 08 ...
Page 158: ...COMPACT CASSETTE TYPE MODELS AU7 AU9 AU12 AU14 AU18 09 09 ...
Page 159: ...CASSETTE TYPE MODELS AU20 AU25 AU30 09 10 ...
Page 160: ...MODELS AU36 AU45 AU54 09 11 ...
Page 161: ...COMPACT WALL MOUNTED TYPE MODELS AS7 AS9 AS12 AS14 09 12 ...
Page 162: ...WALL MOUNTED TYPE MODELS AS18 AS24 AS30 09 13 ...
Page 163: ...HEAT PUMP TYPE MODEL AO54UJ 9 3 2 OUTDOOR UNIT 09 14 ...