Trouble shooting 6
INDOOR UNIT
INDOOR UNIT
Error Method:
Error Method:
HEAT EXCHANGER (Inlet)
THERMISTOR ABNORMAL
Detective Actuators:
Detective Actuators:
Heat exchanger Temperature Thermistor
Detective details:
Detective details:
If open Heat exchanger temp. thermistor is detected at the power on, or
when SHORT Heat exchanger temp. thermistor is detected at the power on.
Check Point 2 : Remove connector and measure the resistance value of thermistor
Check Point 2 : Remove connector and measure the resistance value of thermistor
Thermistor characteristics (Approx)
Turn off the main power, replace the thermistor is it was open or short, then turn on the main power.
31.7
35
39.5
30
49.6
62.9
80.2
103.3
134.2
176.0
Resistance Value ( )
k
25
20
15
10
5
0
Temperature ( )
17.0
20.8
25.6
Resistance Value ( )
k
50
45
40
Temperature ( )
Indicate or Display:
Indicate or Display:
Indoor Unit :
Operation LED
3 Times Blink
3 Times Blink
,
,
Timer LED
Flash
Flash
Swing LED
1 time Blink
1 time Blink
Outdoor Unit :
LED1
Flash,
LED6
1 8TIMES Blink (Indoor Unit address)
ERROR CODE :
E:06
E:06
Forecast of Cause
Forecast of Cause:
1. Connector connection failure
2. Thermistor failure
3. Control PCB defective
Check Point 1 : Check the installation work
Check Point 1 : Check the installation work
Removed connector
Incorrect wiring
Thermistor cable is cut off
When reworking on loose connector, incorrect wiring, keep the power shut off.
Check Point 3 : Check DC5.0V of Control PCB voltage
Check Point 3 : Check DC5.0V of Control PCB voltage
Check each indoor unit circuit diagram, and check the
voltage at both terminal of thermistor.
Heat exchanger Temp Thermo (Wire: BLACK)
Heat exchanger Temp (Mid)Thermo. (Wire:GRAY)
Room temp. thermo (Wire: BLACK)
Cassette Duct Wall Mounted (Except M3) Indoor unit wiring diagram
M3 Chassis Wiring Diagram(Direct soldering to Control PCB) No wiring connector.
If it is not possible to check the voltage, replace Control PCB and set up the original address.
Heat exchanger Temp Thermo (Wire: BLACK)
Heat exchanger Temp (Mid)Thermo. (Wire:GRAY)
Room temp. thermo (Wire: BLACK)
06-11
Summary of Contents for AO54FJ
Page 5: ...1 TEST RUN TM SERIES R410A ...
Page 14: ...2 FUNCTION OF PRINTED CIRCUIT BOARD TM SERIES R410A ...
Page 39: ...3 INVERTER CONTROL TM SERIES R410A ...
Page 45: ...4 OUTDOOR UNIT OPERATION CONTROL TM SERIES R410A ...
Page 54: ...5 INDOOR UNIT OPERATION TM SERIES R410A ...
Page 70: ...6 TROUBLE SHOOTING TM SERIES R410A ...
Page 128: ...7 INSTALLATION TM SERIES R410A ...
Page 140: ...8 REFRIGERANT CAUTION R410A TM SERIES R410A ...
Page 149: ...9 APPENDING DATA1 UNIT TM SERIES R410A ...
Page 156: ...LOW STATIC PRESSURE DUCT TYPE MODELS AR25 AR30 ARXB25 ARXB30 09 07 ...
Page 157: ...MODELS AR36 AR45 09 08 ...
Page 158: ...COMPACT CASSETTE TYPE MODELS AU7 AU9 AU12 AU14 AU18 09 09 ...
Page 159: ...CASSETTE TYPE MODELS AU20 AU25 AU30 09 10 ...
Page 160: ...MODELS AU36 AU45 AU54 09 11 ...
Page 161: ...COMPACT WALL MOUNTED TYPE MODELS AS7 AS9 AS12 AS14 09 12 ...
Page 162: ...WALL MOUNTED TYPE MODELS AS18 AS24 AS30 09 13 ...
Page 163: ...HEAT PUMP TYPE MODEL AO54UJ 9 3 2 OUTDOOR UNIT 09 14 ...