(2) Horizontal Air Direction Adjustment
This instructions are applicable to "LARGE CEILING TYPE",
"UNIVERSAL FLOOR/CEILING TYPE", "WALL MOUNTED TYPE"
and "CEILING WALL TYPE".
Press the HORIZONTAL AIR FLOW DIRECTION SET button.
Each time the button is pressed, the air direction range will
change as follows:
The remote controller's display does not change.
WALL MOUNTED TYPE
Example
: When set to horizontal air direction.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.
During Cooling mode : Horizontal flow
During Heating mode : Downward flow
During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal ,
the air direction cannot be adjusted during this period.
Instructions relating to "the indoor unit's indicator lamp" ( ) are applicable to "CASSETTE TYPE",
"WALL MOUNTED TYPE" and "COMPACT WALL MOUNTED TYPE".
Begin air conditioner operation before performing this procedure.
To select Vertical airflow SWING Operation
This instructions are applicable to "CASSETTE TYPE", "WALL MOUNTED TYPE" and
"COMPACT WALL MOUNTED TYPE".
1
4
1
1
2
3
4
5
05-05
1
2
3
4
5
Press the VERTICAL SWING button for more than two seconds.
The remote controller's VERTICAL SWING lamp (orange) **and
indoor unit's SWING indicator lamp (VERTICAL SWING)
(orange) will light up.
In this mode, the UP/DOWN air direction flaps will swing automat-
ically to direct the air flow both up and down.
Example
: When set to vertical swing.
5-3-2 Swing Operation
DAY OFF
DELETE
SET
ENERGY
SAVE
SET BACK
DAY
CLOCK ADJUST
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
DAY OFF
DELETE
SET
ENERGY
SAVE
SET BACK
DAY
CLOCK ADJUST
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
START/STOP
TIME ADJUST ACL
SET SWING
SET
SWING
MASTER
CONTR
OL
CONTR
OL
FA
N
SET
SET
TEMP
.
TIME
6
or
START/STOP
TIME ADJUST ACL
SET SWING
SET
SWING
MASTER
CONTR
OL
CONTR
OL
FA
N
SET
SET
TEMP
.
TIME
Summary of Contents for AO54FJ
Page 5: ...1 TEST RUN TM SERIES R410A ...
Page 14: ...2 FUNCTION OF PRINTED CIRCUIT BOARD TM SERIES R410A ...
Page 39: ...3 INVERTER CONTROL TM SERIES R410A ...
Page 45: ...4 OUTDOOR UNIT OPERATION CONTROL TM SERIES R410A ...
Page 54: ...5 INDOOR UNIT OPERATION TM SERIES R410A ...
Page 70: ...6 TROUBLE SHOOTING TM SERIES R410A ...
Page 128: ...7 INSTALLATION TM SERIES R410A ...
Page 140: ...8 REFRIGERANT CAUTION R410A TM SERIES R410A ...
Page 149: ...9 APPENDING DATA1 UNIT TM SERIES R410A ...
Page 156: ...LOW STATIC PRESSURE DUCT TYPE MODELS AR25 AR30 ARXB25 ARXB30 09 07 ...
Page 157: ...MODELS AR36 AR45 09 08 ...
Page 158: ...COMPACT CASSETTE TYPE MODELS AU7 AU9 AU12 AU14 AU18 09 09 ...
Page 159: ...CASSETTE TYPE MODELS AU20 AU25 AU30 09 10 ...
Page 160: ...MODELS AU36 AU45 AU54 09 11 ...
Page 161: ...COMPACT WALL MOUNTED TYPE MODELS AS7 AS9 AS12 AS14 09 12 ...
Page 162: ...WALL MOUNTED TYPE MODELS AS18 AS24 AS30 09 13 ...
Page 163: ...HEAT PUMP TYPE MODEL AO54UJ 9 3 2 OUTDOOR UNIT 09 14 ...