52 Electrical
Installation
AXIOM
™
/ AXIOM-X
™
Product Line Manual
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Power Connections Using Other Power Supplies
IMPORTANT:
All non Accu-Sort power supplies, whether for single or
multiple reader applications, must be an LPS or Class 2 power supply. The
supply must provide 30 watts (12-30 VDC) of power to
each
reader.
Single Reader
When a single reader application uses
a non Accu-Sort
supply
, follow the INPUT POWER wiring table to assure proper wiring.
Multiple Readers
When using
a non Accu-Sort supply
with multiple
readers:
1. Follow the INPUT POWER wiring table to assure proper wiring to the
first reader in the wiring daisy-chain.
2. By using the OUTPUT POWER terminal block, a total of three readers
may share a power source. NO MORE than three readers may be daisy-
chained to one power source.
3. Wire a cable from the OUTPUT POWER of the first reader to the INPUT
POWER of the second reader.
4. Wire a cable from the OUTPUT POWER of the second reader to the
INPUT POWER of the third reader.
5. Wiring MUST be grounded at both ends of the INPUT POWER and
OUTPUT POWER connection
.
Output Power Wiring
CAUTION:
The OUTPUT POWER wiring table indicates a maximum 2.5A
output load. This is only for applications using other power supplies
providing a minimum of 86.5 W of power.