Cable and Conduit Connections
Determine the wiring connections needed for your application. All permanent
connections are made to the wiring base with either cables or through
conduit. Wiring bases are shipped with four (4) cord grips and three (3) hole
plugs. Follow Accu-Sort’s wiring recommendations.
Connection
Recommended Wiring Type
Max. Length
Safety Earth
Ground
For 15-20 Amp branch circuit, use #18 AWG min.
For 16-25 Amp branch circuit, use #14 AWG min.
For 26-32 Amp branch circuit, use #12 AWG min.
Power
#20 AWG minimum
RS232
#24 AWG minimum
50’ [15.2]
RS422
#24 AWG minimum
1000’ [300]
Ethernet
#24 AWG CAT5 UTP (unshielded twisted pair)
330’ [100]
Tach / Trigger
#24 AWG minimum
I/O Modules
Depends upon module rating. See
Appendix A
.
NOTE
: ALL external wiring must be UL listed or recognized rated VW-1 or FT-1 and
conforming to NEC ANSI/NFPA 70.
Cord Grips
Recommended Wiring Diameters
Small Diameter
Accommodates 0.191 to 0.354 inches [4.9 to 9.0 mm]
Large Diameter
Accommodates 0.236 to 0.472 inches [6.0 to 12.0 mm]
Cable Connections to Wiring Base
Where the cabling enters the wiring base, use the supplied cord grips
with rubber grommets.
Each cord grip comes with two different size grommets. Use the
grommet size that provides the tightest fit.
NOTE:
To maintain the unit’s IP rating, only one cable may be run through
each conduit opening. If running two or more cables into one opening, use
a plumbing “T” connector to assure the reader will be watertight.
Make sure you use Teflon tape (or other thread sealant) to maintain the
reader’s IP rating. (AXIOM is IP65, AXIOM-X is IP54.)
Once all cabling is completed, plug all unused wiring base openings.