background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medio P200L Reader 

User's Guide 

Revision 1.0

 

 

 

 

August 2010 

 

 

Summary of Contents for Medio P200L

Page 1: ...Medio P200L Reader User s Guide Revision 1 0 August 2010 ...

Page 2: ...ATION CONTAINED HEREIN INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT IN NO EVENT SHALL TAGSYS BE LIABLE WHETHER IN CONTRACT TORT OR OTHERWISE FOR ANY INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE DATA PROFITS REVENUES OR CUSTOMERS ARISING OUT OF OR...

Page 3: ...me desk at Telephone 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 E Mail info tagsysrfid com Website http www tagsysrfid com Contact for Comments We welcome your feedback to help us provide high quality documentation For technical comments please contact our welcome desk Telephone 33 0 4 42 18 89 00 Fax 33 0 4 42 18 89 01 E Mail info tagsysrfid com Please remember to quote the Document Reference Numb...

Page 4: ...ements stringent quality controls at all stages of its manufacturing process However should you find a defect with this product please notify your TAGSYS Quality Service representative using the dedicated Product Return Form Telephone 33 0 4 42 18 89 36 Fax 33 0 4 42 18 89 01 ...

Page 5: ...________________________________________________ 9 2 2 1 IN EUROPE CE AND RTTE DIRECTIVES _____________________________________________ 9 2 2 2 IN USA FCC DIRECTIVE _________________________________________________________ 10 2 2 3 FCC ID CROSS REFERENCE TABLE ________________________________________________ 10 2 2 4 IN CANADA _____________________________________________________________________ 1...

Page 6: ...BSOLUTE MAXIMUM RATINGS______________________________________________________ 22 7 2 DC CHARACTERISTICS ____________________________________________________________ 22 8 WARRANTY CONDITIONS ________________________________________________________ 23 8 1 WARRANTY______________________________________________________________________ 23 8 2 WARRANTY EXCLUSIONS ________________________________________...

Page 7: ... below will further increase the lifetime of this device Keep the device and all parts and accessories out of the reach of small children Keep the device dry Precipitation humidity and liquids contain minerals that will corrode electronic circuits Do not use or store the device in dusty dirty areas Its moving parts can be damaged Do not store in hot areas High temperatures can shorten the life of ...

Page 8: ...Operating Environment When connecting the device or any accessory to another device read its user s guide for detailed safety instructions Do not connect incompatible products As with all RF equipment users are advised that the equipment should only be used in its normal operating position ...

Page 9: ... and 38 dBµA m in US The Medio P200L meets these limits 2 2 1 In Europe CE and RTTE Directives The Medio P200L complies CE Declaration of Conformity granted with the European EMC directive The Medio P200L complies with the requirements of the Telecommunication Terminal Equipment Act FTEG and the RTTE Directive 1995 5 EC It is the responsibility of the TAGSYS Reseller to install the Medio P200L as ...

Page 10: ... separation between the equipment and receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help NO UNAUTHORIZED MODIFICATIONS 47 CFR Section 15 21 CAUTION This equipment may not be modified altered or changed in any way without signed written permission from TAGSYS SA Unauthorize...

Page 11: ...ould be so chosen that the equivalent isotropically radiated power e i r p is no more than that permitted for successful communication This device has been designed to operate with the antennas listed below and having a maximum gain of 35 dBi Antenna not included in this list or having a gain greater than 35 dBi are striclly prohibited for use with this device The require antenna impedance is 50 o...

Page 12: ...t Chromium Polybrominated biphenyl flame retardants Polybrominated diphenyl ether flame retardants This declaration is based on information provided by our suppliers and subcontractors 2 3 2 WEEE Waste Electrical and Electronic Equipment This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to Europe...

Page 13: ... self check stations The Medio P200L Tag readers are easy to integrate because of its small size USB 1 1 communication link 3 2 Medio P200L Key Features Table 1 Medio P200L Key Features Description Medio P200L Operating Frequency 13 56 MHz Compatibility C210 C240 C270 C370 C370L C370S and ISO 15693 chips Serial Link USB 1 1 Network Operating Yes Firmware upgradeable Yes 3 3 Delivery The Medio P200...

Page 14: ...dows XP 200x Vista Seven User friendly Px Explorer software provided for test and debug operations on Windows XP 200x Vista and Seven platforms Tagsys Software Development Kit including o DLLs and ActiveX o Library Software Development Kit Documentation o One set of source code and executable samples 1 Welcome Letter Product Return Form ...

Page 15: ...e 1 below shows the front panel which is dedicated to the RF connection Any of the following antennas can be connected to the standard SMA connector LW 1 Aero LI L SA3 L SA4 L SA4 SHD Figure 1 Front panel The red LED turns on when the reader is supplied 4 1 2 Rear Panel The USB serial communication link and the power supply connector are located on the rear panel as shown below Figure 2 Rear panel...

Page 16: ...ime and click next to proceed with the installation Select Install from a list or specific location Advanced and then click Next Select Search for the best driver in these locations and click the Browse button to select the TAGSYS USB Drivers folder on the Product CR Rom Then click Next to proceed Windows should then display a message indicating that the installation was successful Click Finish to...

Page 17: ...tag to be used In addition Px Explorer can display additional information such as the Product Reference and Firmware version and revision This section describes how to start with Px Explorer 5 1 Installing Px Explorer To install Px Explorer software insert the product CD ROM into the disk drive on your PC and run the Setup from the Software Px Explorer folder and click Next Click the Browse button...

Page 18: ... 18 25 Revision 1 0 August 2010 Once the correct folder is selected click Next Click Next to start the installation process A shortcut will be created on your desktop and a program group will be created in the start menu ...

Page 19: ...k yes Open the Communication Settings window CTRL C and check the COM port number and the communication speed The default communication speed for the Medio P200L is 115200 Bauds Click OK Now Px Explorer is ready to communicate with your Medio P200L 5 3 Reading and Writing a Tag Px Explorer includes a Wizard function used to guide you each step of how to read or program a tag We recommend using the...

Page 20: ... the Detect button to automatically detect the tag type Select the desired operation Read or Write and then click OK All the necessary windows to perform the desired action will be automatically displayed on the screen For more details concerning Px Explorer select the info menu and click Help CTRL H to display the Px Explorer User s Guide ...

Page 21: ...4 8 x 2 7 x 1 2 inches Weight 150 g DC power 12 VDC nominal Chip compatibility C210 C240 C270 C370 C370L C370S ISO 15693 Communication interface USB 1 1 RF Output Power 1W Typical Power consumption 3 6 W Operating temperature 0 to 55 C Storage temperature 20 to 70 C Conformity ETSI 300 330 European Radio compliance EN 50364 FCC part 15 Communication protocol TAGSYS specific STXE 2 ...

Page 22: ...AERO LI 271 mA LSA 2 290 mA IRFOn Supply Current RFOn VSupply 12V Antenna connected LSA 3 276 mA IOpen Supply Current RFOn No connection on RF Connector 202 MA TOp Operating Tempature 0 55 C VUSB Supply Voltage on USB cable 5 25 5 4 35 V IUsb Supply Current on USB cable 25 20 mA UVOH D D Static Output high 3 6 2 8 V UVOL D D Static Output low 0 3 0 V UVSE Single Ended Rx Threshold 2 0 0 8 V UVCOM ...

Page 23: ... as defective by TAGSYS and returned according to the return procedure defined below in such case TAGSYS will at TAGSYS option either replace every defective Product by one new Product or refund the purchase price paid by Buyer to TAGSYS for the defective Product 8 2 Warranty Exclusions Defects or damages resulting from storage of the Product under conditions which do not comply with TAGSYS specif...

Page 24: ... warranties of merchantability and fitness for a particular purpose 8 2 2 How to Return Defective Products The Buyer shall notify TAGSYS of the defects within 15 working days after the defects are discovered Defective Products must be returned to TAGSYS after assignment by a TAGSYS Quality Department representative of an RMA Return Material Authorization number No Products shall be returned withou...

Page 25: ...France To inform TAGSYS of this return please also fax it to your Customer Service Representative 33 0 4 42 18 89 01 Return Procedure The product returned will go through stringent quality controls A final analysis report will be sent to you as soon as possible Please contact your Quality Service representative for further details 33 0 4 42 18 89 36 This product bears the selective sorting symbol ...

Reviews: