EtherNet/IP Options
When EtherNet/IP is enabled, new parameters become available within
AXCESS that allow you to configure some additional options.
These parameters are described in more detail earlier in this manual, but a
quick overview provides some context here. (See
Chapter 5
.)
The
Bar Code Data
parameters allow you to manipulate the format of the
bar code data. Most notable if your bar codes only contain numeric digits,
you can configure the AXIOM to convert the bar codes to a numeric value
instead of transmitting them as ASCII text.
Additionally, you can enable the On-Demand Messaging Option for
ControlLogix Processors. This is described in more detail later in this
document.
If the EtherNet/IP
Trigger Input
is enabled, the AXIOM Trigger settings are
ignored and the AXIOM is triggered solely by manipulating the Trigger Bit in
the Output Word (contained in the AXIOM Assembly and Output Objects).
The
AXIOM Outputs
function the same as AXIOM relay outputs, but they
manipulate bits within the AXIOM Input Word (contained in the AXIOM
Assembly and Input Objects).
The AXIOM can relinquish control of the internal AXIOM relays to another
EtherNet/IP device. When this has been done, these relays are controlled by
bits within the Output Word.