194 Appendices
AXIOM
™
/ AXIOM-X
™
Product Line Manual
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
AXIOM:C Configuration Data
This data is not used.
AXIOM:I Input Data
Tag Name
Value
Description
AXIOM:I.Data[0]
Discrete Input Word
See bit definitions.
AXIOM:I.Data[1]
Bar Code Sequence Number
This field is updated every time the bar code
data is updated. However, the bar code data
will only be updated when the “Last Bar Code
Sequence Number” (see Output Data) is set
equal to this value.
AXIOM:I.Data[2]
Bar Code Status
Not currently used.
AXIOM:I.Data[3]
Bar Code Size (words)
Number of words which contain the bar code
data
AXIOM:I.Data[4-67]
Bar Code Data
Discrete Input Word
Bit
0
AXIOM Programmable Output #1
1
AXIOM Programmable Output #2
2
AXIOM Programmable Output #3
3
AXIOM Programmable Output #4
4
AXIOM Programmable Output #5
5
AXIOM Programmable Output #6
6
AXIOM Programmable Output #7
7
AXIOM Programmable Output #8
8-15 Unused
AXIOM:O Output Data
Tag Name
Value
Description
AXIOM:O.Data[0]
Discrete Output Word
See bit definitions.
AXIOM:O.Data[1]
Last Bar code Sequence
Number Received
This field must be updated to match the Bar Code
Sequence Number each time the bar code data
has been processed.
Discrete Output Word
Bit
Bit = 0
Bit = 1
0*
Trigger Off
Trigger On
1 – 7
Unused
Unused
8*
AXIOM Relay #1 Off
AXIOM Relay #1 On
9*
AXIOM Relay #2 Off
AXIOM Relay #2 On
10*
AXIOM Relay #3 Off
AXIOM Relay #3 On
11*
AXIOM Relay #4 Off
AXIOM Relay #4 On
12-15 Unused
Unused
* If enabled on AXIOM