General Electrical Installation Guidelines
It is important that you follow these general precautions when installing,
setting up, operating, maintaining, troubleshooting or replacing any Accu-
Sort products, parts or related equipment.
CAUTION:
The AXIOM / AXIOM-X use lasers for bar code scanning. Do
not view directly with optical instruments (binoculars or telescopes). Avoid
unintentional exposure to laser light whenever possible.
As you plan and install your AXIOM bar code solution application, be sure to
keep the following guidelines in mind:
Determine the reader is in the proper orientation and position as outlined
in Chapter 3.
Allow approximately 8-12 inches [203-305 mm] of clearance for wiring.
The wiring base has four conduit openings. Seal unused openings. Use
cord grips with rubber grommets on cables that enter the wiring base.
Route wires carefully to reduce or minimize electrical noise. When power
and communication wiring must cross, make their intersection
perpendicular.
Proper grounding of the wiring base limits the effects of noise due to
Electromagnetic Interference (EMI).