96 Setup
AXIOM
™
/ AXIOM-X
™
Product Line Manual
Accu-Sort Systems, Inc.
05-AXIOM-AXIOM-X_Setup_R10.doc
I/O Options
Outputs are the most common uses for the I/O options (e.g., use to activate
diverters, beacon lights, alarms, etc. when specific conditions occur). The
only input options are to indicate an end trigger or custom signals.
Input
Definition
Custom Input
User-defined signal sent to AXIOM (requires custom
software)
End Trigger
Only available at I/O#1 if the Trigger Source is set to
Hardware Start/End Trigger. Active when trigger signal
ends (i.e., photoeye no longer blocked).
Learn Match Code
When this input is active, the AXIOM is placed into Test
Mode in order to “learn” a match code. When the line is
deactivated, Test Mode is exited. When this option is
enabled, the last code read is stored in the first entry of the
Match Table.
Height Tracking
Photoeye
Used in applications requiring Height Tracking Photoeyes.
Up to three photoeyes may be used to divide the AXIOM’s
depth of field into up to four zones. The
Distance from
scanner
(in inches) must also be set.
(See Chapter 3. See
Mounting the Height Tracking Photoeyes.)
CAUTION:
If you get this message when saving
parameters, they should be corrected before saving them.
CAUTION:
If you get this message when retrieving
parameters, you should correct and save them before use.
Output
Definition
Custom Output
Used for applications involving custom software to select a
customized output option.
Life Light
Always on while the reader is operating.
Trigger Output
Echoes the status of the trigger signal.
Error Light
Active in the event of an error condition (see later section
on errors currently detected).
Good Read Output
Active if all expected codes are read.
No-Read Output
Active if not all expected codes are read.
Match Output
Active if any code matches the match code criteria.
No Match Output
Active if no codes match the match code criteria (includes
no-reads).
Good Read and No-
Match Output
Active if a code was read but did not match the match code
criteria.
Multiple Output
Active is too many codes were read.
Multiple or NoRead
Output
Active if too many codes were read or a no-read occurred.