AXIOM
™
/ AXIOM-X
™
Product Line Manual
Electrical
Installation
55
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
Tachometer Connections
In applications where product tracking is required, a tachometer is typically
used. Connect the tachometer wiring to the wiring base terminal blocks.
Wiring Tachometer Input to Wiring Base
When a tachometer is required, the Accu-Sort tachometer is recommended.
Wire this tachometer as indicated in shaded area of the table below.
(Wire
colors indicated for standard NPN Output, shown in shaded areas.)
Tachometer Wiring
TACH WIRE COLOR
TERM
NPN OUTPUT
PNP OUTPUT
24V
WHT/ORG
V +
Supply Voltage
Supply Voltage
(Jumper to V+)
TACH +
Jumper to V+
Tach Output
+ Output
WHT/BLU
TACH -
Tach Output
Jumper to GND
- Output
BLU/WHT+ORG/WHT
GND
Common Common
WARNING:
The maximum tachometer current should not be more than
0.3 amps @ 24 volts.
The shielding for the tachometer wiring MUST be terminated to earth ground.
Otherwise, belt static could result in a system failure.
Tachometer Shielding Terminated to Earth Ground
If your application uses a tachometer other than the one available from Accu-
Sort, follow the TACH wiring table to assure proper wiring.