116 Setup
AXIOM
™
/ AXIOM-X
™
Product Line Manual
Accu-Sort Systems, Inc.
05-AXIOM-AXIOM-X_Setup_R10.doc
Toolbar
The toolbar buttons (from left to right) and the actions they perform are
outlined in the table provided below.
AXCESS Toolbar Button Descriptions
Button
Function Definition
Connect
Use to connect your computer with the AXIOM so you
can use the AXCESS setup software. (The button, as
shown in the above example, indicates there is no
connection to a reader.) Be sure the setup
programming cable is connected to both the computer
and AXIOM or the No Connection message is
displayed.
Save Parameters to
AXIOM
Use to send any changes you made using AXCESS to
the AXIOM scan head’s parameter storage module.
This is the set of parameters the AXIOM uses during
operations.
Retrieve Parameters
from AXIOM
Use to retrieve the reader’s current parameters to
AXCESS.
Save Parameters to Disk
Use to save a copy of the parameters from AXCESS
to disk.
Retrieve Parameters
from Disk
Retrieves a set of parameters from disk.
Backup AXIOM
Parameters to Base
Use to save the scan head parameters to the wiring
base. This enables you to keep a parameters backup
in the wiring base in case you need to: 1) return the
scan head to those parameters, or 2) configure a
replacement scan head with identical parameters.
Restore AXIOM
Parameters from Base
Retrieves the current parameters stored in the wiring
base. Use this function to restore the parameters in
the wiring base to the existing scan head or a
replacement scan head.
Default AXIOM
Parameters
Use to return the reader’s parameters to the
hardcoded "default" values built-in to the reader
software.
For additional information, reference Save / Retrieve Settings in this chapter.