200 Appendices
AXIOM
™
/ AXIOM-X
™
Product Line Manual
Accu-Sort Systems, Inc.
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Assembly Object (04
HEX
– 4 Instances)
Class Attributes
Attribute ID
Name
Data Type
Data Value
Access
Rule
1 Revision
UINT 1
Get
2 Max
Instance
UINT 81
Get
Instance 0x64 Attributes (Input Instance 1)
Attribute ID
Name
Data Type
Default
Data Value
Access
Rule
3 Input
Data
Structure of:
Discrete Input Word (see below)
Bar code Sequence Number
Bar code Status (reserved)
Bar code Size Word
Bar code Data [UINT]
UINT
UINT
UINT
UINT
UINT [ ] varies
(up to 64)
0
0
0
0
0
Get
Discrete Input Word
Bit
0
AXIOM Programmable Output #1
1
AXIOM Programmable Output #2
2
AXIOM Programmable Output #3
3
AXIOM Programmable Output #4
4
AXIOM Programmable Output #5
5
AXIOM Programmable Output #6
6
AXIOM Programmable Output #7
7
AXIOM Programmable Output #8
8-15 Unused
Instance 0x70 Attributes (Output Instance 1)
Attribute ID
Name
Data Type
Default
Data Value
Access
Rule
3 Output
Data
Structure of:
Discrete Output Word (see below)
Last Bar code Seq. Num Received
UINT
UINT
0
0
Get / Set
Discrete Output Word
Bit
Bit = 0
Bit = 1
0*
Trigger Off
Trigger On
1 – 7
Unused
Unused
8*
AXIOM Relay #1 Off
AXIOM Relay #1 On
9*
AXIOM Relay #2 Off
AXIOM Relay #2 On
10*
AXIOM Relay #3 Off
AXIOM Relay #3 On
11*
AXIOM Relay #4 Off
AXIOM Relay #4 On
12-15 Unused
Unused
* If enabled on AXIOM
Instance 0x80 Attributes (Configuration Instance)
Most I/O clients include a Configuration path when opening an I/O connection to a server. There is no
Configuration data needed.
Instance 0x81 Attributes (Heartbeat Instance – Input Only)
This instance allows clients to monitor input data without providing output data.
Common Services
Implemented for
Service Code
Class Level
Instance Level
Service Name
0E
HEX
Yes
Yes
Get_Attribute_Single
10
HEX
No
Yes
Set_Attribute_Single